(3) Filling
Determine the filling quantity first according to the freezer being
repaired. (Each small mark of the liquid tube is 25g, each big mark is 100g).
Open all related valves.
When the liquid level has reached filling quantity, close valves.
(4) Test run
After filling, turn on power to freezer for test run. Observe the unit
operation.
Switch off power.
12.6 Freezer noise
12.6.1 Freezer noise sources
Freezer noise comes from the expanding with heat and contracting with
cold of compressor, evaporator or condenser; from the contacting or
resonance of pipes; from the flowing of refrigerant; or from the vibration of
freezer because the floor is not level, etc.
MAINTENANCE SERVICE AND TROUBLE SHOOTING
Maintenance Service and Trouble Shooting
12.6.2 Compressor