Haier AF122XCEAA Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Kondicionéry Haier AF122XCEAA. haier AF122XCEAA User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 17
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
AF072XCEAA
AF092XCEAA
AF122XCEAA
AF142XCEAA
Console Type
No.0010577698
R
oom Air-conditioner indoor units
OPERATION AND INSTALLATION MANUAL
Please read this operation manual before using the air conditioner.
Please keep this manual carefully and safely.
Zobrazit stránku 0
1 2 3 4 5 6 ... 16 17

Shrnutí obsahu

Strany 1 - Console Type

AF072XCEAAAF092XCEAAAF122XCEAAAF142XCEAAConsole TypeNo.0010577698Room Air-conditioner indoor unitsOPERATION AND INSTALLATION MANUALPlease read this op

Strany 2 - Table of Contents

Is the air filter dirty? Normally it should becleaned every 15 days.Are there any obstacles before inlet and outlet?Is temperature set correctly?Are t

Strany 3 - Cautions

9Installation Manual of Room Air ConditionerPlace where it is easy to route drainage pipeand outdoor piping.Place ,away from heat source and with less

Strany 4

Installation Manual of Room Air Conditioner10Double-spanneroperationFixing of the unit1. Position of the wall hole Wall hole should be decided acco

Strany 5

Installation Manual of Room Air Conditioner11Piping connection of the indoor unit1. Arrangement of piping and drainage pipe After opening inlet gr

Strany 6

12Installation Manual of Room Air ConditionerElectric wiring :When connecting indoor and outdoor wire, check the number on indoor and outdoor terminal

Strany 7 - Parts and Functions

132.Piping cutting and flaringBe sure to carry out deburring after cutting with a pipe cutter.Insert flaring tool to make a flare.Installation inspect

Strany 8 - Operation hints

14Resumable failures are marked with " ", the others are not resumable failures.Resumable failure will disappear when the failure is elim

Strany 9 - Maintenance

HAIER GROUPQingdao Haier Air Conditioner Electric Co., Ltd.Address: Haier Garden ,Qianwangang Road , Economic Development Zone, Qingdao

Strany 10 - Trouble shooting

MaintenanceInstallation Manual of Room Air ConditionerTrouble shootingTable of Contents789-1456Cautions1-4Parts and FunctionsOperation hints

Strany 11 - Tool necessary

1Disposal of the old air conditionerBefore disposing an old air conditioner thatgoes out of use, please make sure it'sinoperative and safe. Unplu

Strany 12 - Fixing of the unit

2 Do not obstruct or cover the ventilationgrille of the air conditioner. Do not putfingers or any other things into theinlet/outlet and swing louve

Strany 13 - Connecting electric cable

3CautionsPlease read the following Safety Instructions carefully prior to use.The instructions are classified into two levels, WARNING and CAUTION acc

Strany 14 - TO POWER SUPPLY

Use of Air ConditionerCautions STRICTENFORCEMENT4When abnormality such as burnt-small found, immediatelystop the operation button and contact s

Strany 15 - Flare tooling die

5Parts and Functions134521.OUTLET2.CONTROL PANEL3.INLET4.FILTER ( inside )5.OUTLETIndoor unit

Strany 16

6Operation hintsPower failure resume (please set and apply as necessary)With setting of power failure resume, if sudden power failure occurs, the unit

Strany 17 - HAIER GROUP

MaintenanceMaintenance at the end of application seasonOn a fine day, unit shall be started and operate inFAN mode for about half a day until the insi